PRICE LIST
PROTECTIVE & SPECIAL APPLICATION RELAYS
|
Sl.No
|
Description
|
Relay type
|
Case
|
Price Rs
|
Price
US $
|
|
01
|
Reverse Power Relays
with Inverse time
Characteristic adjustable setting
|
|
|
|
|
| |
1 – Element
|
ACCUM31
|
1 N
|
4,900
|
98
|
| |
3 – Element
|
ACCUM33
|
3 NH
|
9,500
|
190
|
| |
|
|
|
|
|
|
02
|
Automatic Power Factor Correction Relays
|
|
|
|
|
| |
KVAr sensing, setting 20%
lag-UPF-20% lead with robust Heavy duty quick make
& break stage contact having 230V AC reversible
motorised switching unit with supply failure
protection and suitable for 415/110V 5 Amps or 1 Amps
TPN 50 c/s system in flush type Nondrawout case with
self testing facility. Type PCR. Extra for
provising P.F. Meter on Relay Rs. 2500/- US $ 120
|
|
|
4 Stage
Rs.
7,400
$ 148
5 Stage
Rs. 7,700 $ 154
6 Stage
Rs. 7,950 $ 159
7 Stage
Rs. 8,250 $ 165
8 Stage
Rs. 8,300 $ 166
9 Stage
Rs. 8,980 $ 180
10 Stage
Rs. 9,330 $ 187
12 Stage
Rs.10,370 $ 207
14 Stage
Rs.12,910 $ 258
20 Stage
Rs.17,250 $ 345
|
| |
|
|
|
|
|
|
03
|
Earth Leakage Relay with CBCT
|
|
|
|
|
| |
Highly sensitive Earth Leakage with
Relay setting 4-12 Amps of Primary current Aux. Supply
230V
|
CIT-11
|
½ N
|
|
|
|
|
With 4" Bore CBCT
|
|
|
1,850
|
37
|
| |
With 6" Bore CBCT
|
|
|
2,640
|
53
|
| |
With 8" Bore CBCT
|
|
|
3,700
|
74
|
| |
|
|
|
|
|
|
04
|
Generator AMF Relay
|
|
|
|
|
| |
(For Automatic starting &
stopping of Generators)
|
AMF-1
|
3 NH
|
7,260
|
145
|
| |
Highly sensitive automatic mains
failure relay comprising of :-
When mains supply fails, it starts
the Engine in 3 kicks of 5 seconds operation/5 seconds
rest. As soon as the generator starts the starting
sequence is switched off. When generator builds up the
rated voltage the generator contacts are switched ON.
When the mains power is resumed it waits for 1 seconds
and thereafter switches off the generator contactor/ACB
& switches ON the mains contactor/ACB and stops
the generator. In case the Engine fails to start after
3 kicks then it closes a contact for starting failure
Alarm annunciation.
|
| |
|
|
|
|
|
|
05
|
Single Kick Start AMF Relay
suitable for small Set below 60 KVA with or without
battery charger
|
AMF-2
|
3NH
|
5,080
|
102
|
| |
|
|
|
|
|
|
06
|
A.C. Instantaneous O/C or E/F Relay
setting
O/C 50-200%, E/F 20-80% or 10-40% of 5A or 1A
|
ACAG12
|
½ N
|
1,500.00
|
30
|
| |
- DO – 3 Element
|
ACAG32
|
1 N
|
4,000.00
|
80
|
| |
- DO – 1 Element Fixed
|
ACAG11
|
|
1,200.00
|
24
|
|
|
|
|
|
|
|
|
07
|
Non-Directional IDMT O/C & E/F Relay
setting O/C 50-200%, E/F 20-80% or 10-40% of 5A or 1A
|
|
|
|
|
| |
1 – Element
|
ACDG11
|
1 N
|
2,800.00
|
56
|
| |
3 – Element
|
ACDG31
|
3 NH
|
7,500.00
|
150
|
| |
- DO – With high set instantaneous acting unit.
|
|
|
|
|
| |
1 – Element
|
ACDG21
|
1 N
|
3,750.00
|
75
|
| |
3 – Element
|
ACDG61
|
3 NH
|
10,500.00
|
210
|
|
|
|
|
|
|
|
|
08
|
Voltage Operated Auxiliary Relay1
– Element
|
AVAA12
|
¼ N
|
1,450.00
|
29
|
| |
With S/R or H/R contact/Flags 2 – Element
|
AVAA22
|
½ N
|
2,100.00
|
42
|
| |
3 – Element
|
AVAA32
|
1 N
|
2,580.00
|
52
|
| |
|
|
|
|
|
|
09
|
Voltage Operated Auxiliary Relay
1– Element
|
AVAG11
|
½ N
|
1,250.00
|
25
|
| |
With or with out flag indication 2 – Element
|
AVAG21
|
½ N
|
1,550.00
|
31
|
| |
110V/230V AC 50 c/s or DC 3 – Element
|
AVAG31
|
1 N
|
2,200.00
|
44
|
| |
|
|
|
|
|
|
10
|
Instantaneous Overvoltage Monitor Relay
|
AVAGM22
|
1 N
|
2,700.00
|
54
|
| |
adjustable setting 90% - 140% single element.
|
|
|
|
|
| |
|
|
|
|
|
|
11
|
Instantaneous Undervoltage Monitor Relay
|
AVAGM23
|
1 N
|
2,900.00
|
58
|
| |
adjustable setting 40% - 100% single element.
|
|
|
|
|
| |
|
|
|
|
|
|
12
|
High Speed Tripping Relay
1 – Element HR
|
AVAJH13
|
½ N
|
1,550.00
|
31
|
| |
2 – Element HR
|
AVAJH23
|
½ N
|
2,350.00
|
47
|
| |
|
|
|
|
|
|
13
|
High Speed Tripping Relay
1 – Element SR
|
AVAJS13
|
½ N
|
1,550.00
|
31
|
| |
2 – Element SR
|
AVAJS23
|
½ N
|
2,350.00
|
47
|
| |
|
|
|
|
|
|
14
|
Fuse Failure Relay
110V AC 50 c/s 1 NO 1 NC
|
AVAPM31
|
1 N
|
4,000.00
|
80
|
| |
|
|
|
|
|
|
15
|
Trip Circuit Supervision Relay
|
AVAX21
|
½ N
|
2,490.00
|
50
|
| |
30, 50, 110 or 230V DC 2 B 1M S/R contact
|
AVAX31
|
½ N
|
3,600.00
|
72
|
| |
|
|
|
|
|
|
16
|
Inverse Time Overvoltage Relay
|
AVDG11
|
1 N
|
3,500.00
|
70
|
| |
Setting 100-140% or 110V AC or 230V AC
|
440V AC
|
|
500.00
|
10
|
| |
|
|
|
|
|
|
17
|
Inverse Time Undervoltage Relay
|
AVDG13
|
1 N
|
3,980.00
|
80
|
| |
Setting 50-90% or 110V AC or 230V AC
|
415V AC
|
|
700.00
|
14
|
| |
|
|
|
|
|
|
18
|
Neutral Displacement Relay
|
ACDG14
|
1 N
|
4,650.00
|
93
|
| |
voltage setting 5,4,7,12.5 and 20 Volts
|
|
|
|
|
| |
|
|
|
|
|
|
19
|
High/Low Power Factor Alarm Relay
|
HPA1
|
1 N
|
3,890.00
|
78
|
| |
|
|
|
|
|
|
20
|
Indoor or Outdoor Model Light Switch/Photo Cell
Switch or Twilight Switch
|
TW
|
|
|
|
|
|
5 Amps
1 Phase
Rs. 860.00
$.17
3 Phase
Rs. 2,000.00
$.40
15 Amps
1 Phase
Rs.1,440.00
$.29
3 Phase
Rs. 3,050.00
$.61
|
| |
|
|
|
|
|
|
21
|
Thermal Maximum Demand Ammeter
|
TMA1
|
|
1,120.00
|
22
|
| |
|
|
|
|
|
|
22
|
Generator Automatic Loading/Unloading Timer
|
VCS3
|
|
5,500.00
|
110
|
|